Overview
Features
Wiring & Remote Installation
Specs
International Approvals
Brochure
Overview
The Xm-5 is the smallest in this series of Voltage and Frequency converters. Providing 5 Amps of regenerated, clean, 120v~60Hz power, it includes all of the same technical features of the larger capacity Xm-10 and Xm-15. Perfect for powering a single appliance or multiple devices whose total load does not exceed 600 Watts (5 Amps).
Xm-5 is a full-featured sine wave output regenerator that produces new, clean, and constant AC power; eliminating line noise and ensuring optimum performance. It is capable of providing 120~60Hz electricity for running a single household appliance or devices whose load does not exceed 600W (5 Amps).
This unit is designed to be Wall Mounted remotely in a convenient location and utilizing the supplied Input Receptacle wired to the supplied single Wall Double Outlet at the point of use.
The Xm-5 features a hardened metal casing.
Power
With sophisticated electronics including power factor correction, as well as input and output EMI and RFI filters, it produces continuous power at over 92% efficiency and with output Harmonic distortion below 3%. High levels of regulation ensure 120~60Hz output with fluctuations below ± 2%, making it the ideal conversion device for taking high-end audio and home theater equipment overseas.
Power for High Performance Audio
To the audiophile, the Xm-5 functions as a Regenerator with Power Factor Correction (PFC). It is a premiere choice for powering audio equipment to satisfy the most demanding audiophiles. With its clean sinewave output (typically < 1%THD) and with virtually no change in amplitude due to input voltage fluctuations and output load transients, audio equipment will always function with optimal performance. Because the output of the Xm-5 regulates so well, another advantage to the audiophile is that other equipment powered by the Xm-5, such as HDTVs and DVRs, will not introduce noise or distortion to the audio output via the common power connection.
Additionally excellent EMI filtering on the input and output of the Xm-5 prevents RFI noise from being injected into the audio output.
Another important feature for audiophiles is the high output surge current capacity (150 Amps) of the Xm-5. This capability to source high surge currents with minimal distortion of the output voltage results with crisp high volume audio transients.
Frequently overlooked is the importance of PFC for noise free operation of audio equipment. Because PFC eliminates voltage and current distortions on the input power leads to the Xm-5, this potential source of audio noise is virtually non-existent.
Reliability
The Xm-5 has sealed, solid-state electronics that protect against humidity and dust, ensuring reliability and a long product life. An External Fan automatically cools the sealed electronics whenever the load exceeds 5 Amps or when environmental factors exceed operating temperature.
Safety
Not only will electrical equipment perform better, but the Xm-5 also acts as an advanced voltage regulator, which fully protects equipment against voltage irregularities, such as under INPUT voltage as low as 180Vac and over voltage as high as 265Vac and provides an appliance with inrush surge protection of up to 150 Amps.
Audible alarms notify overload, short circuit and temperature.
The Xm-5 not only meets the stringent standards of the UL and FCC in the USA, but also meets International Safety Standards.
- Frequency Converter
- Voltage Converter
- Sophisticated Voltage Regulator
- Surge Protection
- Short Circuit Protection
- Over-Current Protection
- Power Factor Correction (PFC)
- Thermal Protection
- Lightweight
- High Efficiency
- Input EMI and RFI Filters
- Output EMI and RFI Filters
- Low Harmonic Distortion
- Sealed, Solid State Electronics
- External Cooling Fan
- Continuous Power
- Audible Alarms
- International Approvals
- Includes Remote Installation Kit
Wiring & Remote Installation
A licensed electrician can help you with the selection and remote installation of the correct model for the intended application.
PowerXchangers can be installed remotely, out of view and to save valuable space. They should be installed in a cool, well-ventilated and unobstructed area for best performance and longevity.
Standard Accessories: Wall Mount, Power Inlet,(1) Power Outlet, Power Connection Cord, (4) Input Cord Type F, G, I, M |
|
Xm-5 |
12060Xm-5 |
Output |
|
Output Voltage |
120Vac |
Output Current-Amps @ 60Hz |
5A |
Voltage Regulation |
± 2% From Setpoint |
Output Frequency |
60Hz (Auto-Synchronized to Mains) |
Crest Factor |
8:1 |
Voltage Waveform |
Sine Wave |
Output Distortion (Resistive Load) |
<2% |
Output Distortion (Reactive Load) |
<3% |
Allowed Peak Current |
40A |
Standby Power |
15W |
Total Harmonic Distortion |
< 3% at 100% Linear Load |
Output EMI Filter |
150Khz - 30Mhz |
Output RFI Filter |
30Mhz - 1000Mhz |
Clamp Level |
190V |
Protection |
|
Over Current Protection |
Over Load Alarm Level: 100% ~ 135% (alarm after 1 minute delay, shutdown after 1 minute alarm) Over Load Shutdown Level: 136% (shutdown after 2 second delay) |
Short Circuit |
Pulsating Type, 40A Peak Auto-Restart time: 30 seconds |
Input |
|
Nominal Voltage |
200V/220V/230V/240V |
Maximum Continuous Load |
600W |
Maximum Peak Load |
1000W |
Input Frequency |
46Hz ̴ 65Hz |
Phase |
Single |
Noise Filtering |
Full-Time EMI/RFI Filtering |
Input EMI Filter |
150Khz -30Mhz |
Input RFI Filter |
30Mhz - 1000Mhz |
Over Current Protection |
By Re-Settable Over Current Protector |
Voltage Range |
180Vac ̴ 265Vac |
Power Factor |
> 0.95 |
Audible Alarm |
Over Load Alarm: Continuous alarm
Short-Circuit Alarm: 1 beep every 2 seconds
Thermo Alarm: Every other 2 seconds, 32 beeps in 2 seconds |
Switch-On Surge (In-Rush Current) |
<150A, 2ms |
Voltage Interruption Ride Through |
30mS |
Efficiency |
>92% |
Indicators |
|
LCD |
Not Applicable |
LED |
Not Applicable |
Environmental and Safety |
|
Operating Temperature |
Up to 2000 Meters: 0° to 45°C (32°F to 113°F) |
Transit/Storage Temp |
-15°C to 60°C (5°F to 140°F) |
Relative Humidity |
5 – 95% Non-Condensing |
Operating Altitude |
0 ~ 3000 Meters |
Moisture Sensitivity |
Sealed Electronics |
Cooling |
|
Natural Ventilation |
Yes |
External Cooling Fan Control |
Auto on/off, controlled by heat sink temperature & load level |
Physical |
|
Product Dimensions L×W×H(cm/in) |
41.50 × 26.50 × 10.00 cm 16.34 × 10.83 × 3.94 in |
Net Product Weight (kgs/lbs) |
9.71 kgs 21.41 lbs |
Carton Dimensions L×W×H(cm/in) |
58.00 x 30.00 x 54.00 cm 22.83 x 11.81 x 21.26 in |
Shipping Weight |
16.53 kgs 36.44 lbs |
Warranty |
2 Years, Full Replacement |
Quality Control Standard |
ISO9001 |
International Approvals |
UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2,
UL 1012, Seven Edition, October 14, 2008
UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001
DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2)
TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1)
FCC Part 15: subpart B
EMC 2004/108/EC |
Some applications may require isolation from main power grid. We can offer PowerXchanger designed and manufactured Isolation Transformer XTI-ISO2K.
If your application is in conjunction with the purchase of a PowerXchanger product we can offer a reduced packaged price.
Please contact us via e-mail contact@adaptivefrequency.com for technical support and pricing.
- UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2,
- UL 1012, Seven Edition, October 14, 2008
- UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001
- DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2)
- TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1)
- FCC Part 15: subpart B
- EMC 2004/108/EC
- PowerXchangers meet IEC Standard 60335-1 and are considered a critical component of an appliance when used with another appliance that also meets the same IEC 60335-1 International Safety Standard
Click here to download product brochure (A new browser window will be opened).